灭火器是压力容器,属于欧盟CE认证中的PED指令2014/68/EU,该指令是针对压力设备的安全指令,凡是设计压力超过0.5bar的设备,无论其压力、容积为何,均须符合PED指令的规定。
灭火器是一种可携式灭火工具。灭火器内放置化学物品,用以救灭火灾。
灭火器是常见的防火设施之一,存放在公众场所或可能发生火灾的地方,不同种类的灭火器内装填的成分不一样,是专为不同的火灾起因而设的,我们使用时必须注意,以免产生反效果及引起生命危险。
灭火器是压力容器,属于欧盟CE认证中的PED指令,该指令是针对压力设备的安全指令,凡是设计压力超过0.5bar的设备,无论其压力、容积为何,均须符合PED指令的规定。
1.干粉灭火器CE认证EN 615的相关规定:EN 615-2009 防火。灭火介质。灭火粉规范(D级粉除外)
2.推车式灭火器需要符合EN 1866,该标准是针对移动式灭火器的安全规定。
3.EN 3-7:灭火器的性能测试标准;
EN 3-8 :粉和泡沫灭火器CE认证;
EN 3-9:二氧化碳灭火器CE认证;
4.灭火器CE认证所执行的现行有效标准如下,
EN 3-7-2004+A1-2007 Portable fire extinguishers-Part 7: Characteristics, performance requirements and test methods
EN 3-7-2004+A1-2007 便携式灭火器。特性、性能要求和试验方法
EN 3-8:2006 Portable fire extinguishers - Part 8: Additional requirements to EN 3-7 for the construcion,resistance to pressure and mechanical tests foiextinguishers with a maximum allowable pressure equal to or lower than 30 bar
EN 3-8:2006便携式灭火器。第8部分:EN3-7MAX大允许压力≤:30bar灭火器结构的耐压和机械试验的附加要求
EN 3-9:2007 Portable fire extinguishers - Part 9: Additional requirements to EN 3-7 for pressure of c02 extinguishers
EN 3-9-2007 手提式灭火器-第9部分:附加要求EN 3-7二氧化碳灭火器耐压
EN 3-10:2009 Portable fire extinguishers. Provisions for evaluating the conformity of a portable fire extinguisher to EN 3-7
EN 3-10:2009 手提式灭火器-第10部分: 评估便携式灭火器符合EN 3-7的规定
BS EN 615:2009 Fire protection. fire extinguishing media. Specifications for powders (other than class D powders)EN 615-2009 防火。灭火介质。灭火粉规范(D级粉除外)
5.另外二氧化碳灭火器的钢瓶还需要满足IS0 9809或者EN 1964的要求。铝瓶灭火器需要满足BS 5045的法规要求。
BS EN IS0 9809-1:2010. Gas cylinders. Refilable seamless steel gas cylinders. Design, construcion and testing. Quenched and tempered steel cylinderswith tensile strength less than 1100 MPa
BS EN IS0 9809-2:2010. Gas cylinders. Refilable seamless steel gas cylinders. Design, construction and testing. Quenched and tempered steel cylinderswith tensile strength greater than or equal to 1100 MPa
BS EN IS0 9809-3:2010, Gas cvinders, Refllable seamless steel gas cylinders, Design, construction and testing. Normalized steel cyinders
BS IS0 9809-4:2014. Gas cylinders. Refllable seamless steel gas cylinders. Design, construction and testing. Stainless steel cylinders with an km value ofless than 1 100 MPa
BS EN 1964-3:2000. Transportable gas cylinders. Specification for the design and construction of refllable transportable seamless steel gas cylinders ofwater capacities from 0,5 litre up to and including 150 itres. Cyinders made of seamless stainless steel with an $iR$dm value of less than 1 100 Mpa
BS 5045-6: 1987. Transportable gas containers. Specification for seamless containers of less than 0.5 litre water capacity
BS 5045-7:2000.Transportable gas containers. Specification for seamless steelI gas containers of water capacity 0.5 L up to 15 L for special portableapplications
6.灭火器的选择
在选择灭火器时应符合下列规定:
6.1、扑救A类火灾应选用水型、泡沫、干粉、卤代烷等灭火器;
6.2、扑救B类火灾应选用干粉、泡沫、卤代烷、二氧化碳等,扑救水溶性B类火灾不得选用化学泡沫灭火器;
6.3、扑救C类火灾应选用干粉、卤代烷、二氧化碳型灭火器;
6.4、扑救带电设备火灾应选用卤代烷、二氧化碳、干粉灭火器;
6.5、扑救A、B、C、类和带电设备火灾应选用干粉、卤代烷灭火器;
6.6、扑救D类火灾应选用专用干粉灭火器。
7.标识
标识一般用印刷的不干胶贴在筒体的外表,标识的检查主要检查标识的内容,是否正确完整。标识的检查内容应该有:
灭火器名称、型号、
灭火级别、使用温度范围、驱动气体数量和名称、
制造厂商名称、灭火器的使用方法等,
认证检验机构的代码,CE标识。
2024年11月5日
2024年11月4日
2024年11月4日
2024年11月1日
2024年10月30日
2024年10月29日
2024年10月12日
2024年10月11日
2024年10月8日
2024年9月30日